Hi,
Ideally the MACD function periods are 12/26/9 days .
I can see period/period2/period3 as 3 periods for the function , which one should i set 12(SMA)/26(long EMA) and 9(signal) .
I have 250,000 datapoints in my graph for time against bid price , the plot for bid price can be as high as 10 times a second , see the attached graph for sample data for a day with 2.5Lakh datapoints.
How can I use the MACD function to do the following .
1) Set the period in Milliseconds for the 3 periods , instead of in days .
2) set the period in dateperiods and/or number of points (i read the helpfile but example will be better).
3) What is the threshold for MACD graph , i mean , beyond hw many datapoints does it break or leak memory (assume 2 GB RAM) . have you done any stress tests for the same . On my machine with 2GB MACD is giving memory issues and CPU(P4 hyperthreaded) usage shoots to 99% .
4) Am not sure what the values of period/period2 and period3 should be , and how i can select a subset of my datapoints for MACD . I mean i should be able to select only the first 20000 datapoints for MACD , then what will be the function call like ?
thanks
aniket
Silverlight : MACD function
-
- Newbie
- Posts: 46
- Joined: Wed Jan 28, 2009 12:00 am
Silverlight : MACD function
- Attachments
-
- FxSample_1day.JPG (56.34 KiB) Viewed 8395 times
-
- Site Admin
- Posts: 14730
- Joined: Mon Jun 09, 2003 4:00 am
- Location: Banyoles, Catalonia
- Contact:
Re: Silverlight : MACD function
Hi Aniket,
Yes, you can use DateTimeSteps like this:1) Set the period in Milliseconds for the 3 periods , instead of in days .
Code: Select all
macd1.Period = Steema.TeeChart.Utils.GetDateTimeStep(Steema.TeeChart.DateTimeSteps.OneMillisecond);
Yes, as described in reply above.2) set the period in dateperiods and/or number of points (i read the helpfile but example will be better).
TeeChart doesn't have limits of any kind when dealing with number of series and number of points on it. The only limit is what the machine where the applications runs can handle. We don't have figures for that as this highly depends on each machine specific configuration.3) What is the threshold for MACD graph , i mean , beyond hw many datapoints does it break or leak memory (assume 2 GB RAM) . have you done any stress tests for the same . On my machine with 2GB MACD is giving memory issues and CPU(P4 hyperthreaded) usage shoots to 99% .
For information on how Period works please read tutorial 7. Tutorials can be found at TeeChart's program group. In that case you should use MACDFunction's Calculate and CalculateMany methods or use a function having a subset of the points as function's datasource.4) Am not sure what the values of period/period2 and period3 should be , and how i can select a subset of my datapoints for MACD . I mean i should be able to select only the first 20000 datapoints for MACD , then what will be the function call like ?
Best Regards,
Narcís Calvet / Development & Support Steema Software Avinguda Montilivi 33, 17003 Girona, Catalonia Tel: 34 972 218 797 http://www.steema.com |
Instructions - How to post in this forum |
-
- Newbie
- Posts: 46
- Joined: Wed Jan 28, 2009 12:00 am
Re: Silverlight : MACD function
thanks Narcis ,
i will take a look at the tutorial and revert .
regards,
aniket
i will take a look at the tutorial and revert .
regards,
aniket